technical specifications 2004
concrete surfaces


Interior and exterior OLD CONCRETE SURFACES, finished with:

RIALTO DOMOSIL


Preparation

Strip any oxidized iron rods appearing on the surface of the reinforced concrete until all rust has been removed. Use a sander to remove the rust and apply immediately on the iron rods RIALTO UNIVERSAL, an anti-rust protective product. Average covering capacity: 100 ml/m². Replace the iron rods whose section has been reduced by more than 30% and weld new ones. Patch with the cement-based mortar RIALTO WALLCEM, mixed with 10% of RIALTO MATONAL (max thickness: 0.5 cm). RIALTO WALLCEM average covering capacity: 1.2 kg/m² per 1mm thickness. Allow the surface to dry completely before proceeding. Apply one coat of the absorption-regulating, water-repellent, anti-saline efflorescence, single-can RIALTO ISOCAL primer, based on oligomeric organosiloxane in aliphatic solvents; average covering capacity: 0,3 l/m².

Finishing
AApply using a brush two coats of RIALTO DOMOSIL, a breathable water-repellent and permanent-action fungicide and bactericide agent, based on siloxane and UV ray-resistant pigments (DIN 53122, 230 g/m² - 24 hours, µ=410, Sd=0.09 m). The first coat should be diluted to 35% with water and the second to 25%. Allow at least 12 hours before applying the second coat.
Average covering capacity: 1 l/5 m².
Price for material and application, excluding any scaffolds, € …….. per m²